DMX300C
High-voltage DMX controller with LCD display is a kind of controller with LCD digital display interface, used for control the RGB color change of 5 line 4 channels(common anode) LED lamps, up to 34kinds of change programs to choose, at the same time can accept DMX-512 international standard digital control. Controller can be stand-alone operation, automatically online, accept standard DMX512 console control signal etc. method to work.
1.Summarization
High-voltage DMX controller with LCD display is a kind of controller with LCD digital display interface, used for control the RGB color change of 5 line 4 channels(common anode) LED lamps, up to 34kinds of change programs to choose, at the same time can accept DMX-512 international standard digital control. Controller can be stand-alone operation, automatically online, accept standard DMX512 console control signal etc. method to work. According to the customer's actual demand, can achieve jumpy changing, gradual changing, stroboscopic such change effect.
2.Technical Parameters
Working temperature: -20-60℃
Power supply voltage: AC 100~240V 50/60HZ
Output voltage: DC 100~240V
Output connect way: common anode 5 line 4 channels
External dimension: L205*W103*H40 mm
Packing size: L225*W120*H55 mm
Net weight: 698.5g
Gross weight: 900g
Static power consumption: <2W
Maximum output current: 4*2A, each circuit has short-circuit protection function and 20% fuse protection for overload.
Dimming frequency: 980Hz
Maximum output power: 880W(input voltage: 110V),1760W(input voltage: 220V)
5.Direction for use
1. Connect the load wire at first, following by the power wire; Please ensure short circuit
can not occur between connecting wire before you turn on the power.
Controller have 4 function setting key: MODE, PARA, UP, DOWN.
2. MODE key choose in turn or press UP, DOWN key to choose:
No. |
Display content |
Instruction |
1 |
BLACK |
Static black |
2 |
STATIC RED |
Static red |
3 |
STATIC GREEN |
Static green |
4 |
STATIC BLUE |
Static blue |
5 |
STATIC YELLOW |
Static yellow |
6 |
STATIC PURPLE |
Static purple |
7 |
STATIC CYAN |
Static cyan |
8 |
STATIC WHITE |
Static white (RGB) |
8-2 |
STATIC WHITE |
Static white (W) |
9 |
COLOR CHANGE |
Seven color jumpy changing |
10 |
COLOR CHANGE2 |
Jumpy changing (flicker) |
11 |
6 COLOR CHANGE |
Six color jumpy changing |
12 |
6 COLOR CHANGE2 |
Jumpy changing (flicker) |
13 |
RGB CHANGE |
Three color jumpy changing |
14 |
RGB CHANGE2 |
Jumpy changing (flicker) |
15 |
RG CHANGE |
RG jumpy changing |
16 |
RB CHANGE |
RB jumpy changing |
17 |
GB CHANGE |
GB jumpy changing |
18 |
WHITE CHANGE |
White stroboflash |
19 |
7 COLOR SMOOTH |
Seven color gradual changing |
20 |
4 COLOR SMOOTH |
Four color gradual changing |
21 |
RG SMOOTH |
RG gradual changing |
22 |
RB SMOOTH |
RB gradual changing |
23 |
GB SMOOTH |
GB gradual changing |
24 |
COLOR GRADUAL |
Seven color fade in and out |
25 |
RGB GRADUAL |
Three color fade in and out |
26 |
WHITE GRADUAL |
White fade in and out |
27 |
YELLOW GRADUAL |
yellow fade in and out |
28 |
PURPLE GRADUAL |
purple fade in and out |
29 |
CYAN GRADUAL |
cyan fade in and out |
30 |
R GRADUAL |
R fade in and out |
31 |
G GRADUAL |
G fade in and out |
32 |
B GRADUAL |
B fade in and out |
33 |
ADJUST MODE |
RGBW 0-255 level color adjustable |
34 |
AUTO PROGRAM COLOR CHANGE2 |
Auto operation selecting result of changing |
35 |
DMX512 MODE |
DMX512 control order |
36 |
DMX512 DECODER |
DMX512 decoder |
3. Press PARA to adjust in turn: (1-8 is static state, do not have adjust function)
No. |
Parameters display |
Instruction |
|
Maximum |
Minimum |
||
1 |
RUN SPEED |
100 |
0 |
2 |
RUN TIMES |
100 |
0 |
3 |
LOAD DEFAULT |
Restore the factory parameter |
4. UP: increase parameter key/preset parameter.
5. DOWN: decrease parameter/preset parameter.
6. AUTO PROGRAM mode is repeatedly cycle running part or all of 7-32 patterns run,you can set whether participating in repeated cycle of operation or not in RUN TIMES.
7. RUN TIMES: compiling the run times of the pattern under 34 AUTO PROGRAM, if the run times is 0, you can skip the pattern,that means not running the pattern.
8. Preset parameter: each form has independent factory preset parameter, which is kept in controller separate. LOAD DEFAULT can recover the factory parameter of the form. If under AUTO PROGRAM mode, using LOAD DEFAULT can unified recover the parameter of all forms to factory parameter.
9. 32 ADJUST MODE is manual dimming, it can adjust the brightness of RGB 0-256 level respectively.
10. 34 DMX512 MODE is controlling all patterns (the first address) and speed(the second address).
11. 35 DMX512 DECODER is DMX decoder, completely accepting outside DMX512 signal to work. Taking 4 addresses, R(the first address), G(the second address), B(the third address), reserved channel(the fourth channel), in need of setting address(by pressing PARA).
7.Remarks
1. Connect the load wire at first, following by the power wire; Please ensure short circuit can not occur between connecting wire before you turn on the power;
2. Power supply voltage range is AC90-240V, more than voltage range maybe burn out the controller.